ISSN print edition: 0366-6352
ISSN electronic edition: 1336-9075
Registr. No.: MK SR 9/7
Published monthly
|
Simulation of Toluene Extractive Distillation from a Mixture with Heptane
P. Steltenpohl, M. Chlebovec, and E. Graczová
Department of Chemical and Biochemical Engineering, Faculty of Chemical and Food Technology,
Slovak University of Technology, SK-812 37 Bratislava
E-mail: steltenp@cvt.stuba.sk
Abstract: Comparison of simulated equilibrium data and extractive distillation simulations accomplished
by the use of different model parameters sources is presented. Sets of experimental binary vapourliquid
and liquid-liquid equilibrium data were used to estimate the binary parameters of the NRTL
model equation. Furthermore, UNIFAC method predicted binary NRTL parameters were obtained
from the HYSYS simulation environment.
Both sets of model parameters were used to model the vapour-liquid equilibrium of ternary
mixture containing heptane, toluene, and N-methylpyrrolidone (NMP). The influence of the NRTL
model parameters on the efficiency of extractive distillation unit used for toluene separation from
a mixture with heptane in the presence of NMP was further investigated.
Simulation of extractive distillation column gave similar results for both sets of NRTL model
parameters when the use of a large quantity of extractive solvent was assumed. However, for solvent
to feed ratio lower than 3, higher separation efficiency of the column was observed for original model
parameters compared to HYSYS supplied ones. This fact seems to correlate with the feed component’s
relative volatility variation with the amount of extractive solvent present in the mixture.
It was found that the source of model parameters influences essentially the quality of binary and
ternary equilibria prediction. Important differences between experimental and modelled equilibrium
data could be expected when unreliable model parameters are used. Especially, model parameters
predicted by the UNIFAC LLE method gave mistaken liquid-liquid and vapour-liquid equilibrium
data fit. As a consequence, at certain simulation conditions the choice of improper phase-equilibrium
model parameters led to wrong separation unit design.
Full paper in Portable Document Format: 596aa421.pdf
Chemical Papers 59 (6a) 421–427 (2005)
|