ISSN print edition: 0366-6352
ISSN electronic edition: 1336-9075
Registr. No.: MK SR 9/7

Published monthly
 

Chalcone-based colorimetric naked eye detection of vanadium in crude oil using a new microfluidic device

Astabraq H. Zaalan, Hanan A. Al-hazam, Hassan T. Abdulsahib, and Zaidon T. Al-aqbi

Department of Chemistry, College of Science, University of Basrah, Basrah, Iraq

 

E-mail: eastabraq.almosawi@gmail.com

Received: 27 July 2024  Accepted: 10 February 2025

Abstract:

Chalcones are a highly effective chelating agent used in spectrophotometric vanadium ion detection. It was observed that potassium (E)-(4-(3-(4-hydroxy-3- methoxyphenyl) acryloyl)phenyl) carbamodithioat (HMAPC) reagent formed a yellow colored complex with vanadium ion at 420 nm. Vanadium ion was chelated with the chalcone (HMAPC) reagent in acidic medium at pH = 6 using Britton–Robinson buffer (BRB). The effect of reagent volume, pH, temperature, time, and interferences was studied. The stoichiometric composition of the formed complex was found to be 1:2 (metal: reagent) by Job's method of continuous variation and mole ratio methods. Beer's law was obeyed in the range of 1–32 µg mL−1 with molar absorptivity of 1589.32 L mol−1cm−1, sensitivity of 0.03225 µg mL−1, regression coefficient of 0.9945 and an estimated detection limit of 0.1354 µg mL−1. The accuracy (recovery percentage) was ranged between 97.2 and 104.8%, and precision (R.S.D.%) is less than 1.5%. A colorimetric method equipped with a portable microfluidic device (µ-chip), as well as a smartphone (iPhone), is used to measure vanadium concentrations. The resulting color changes were taken by a smartphone camera. The obtained images were analyzed by ImageJ software to assay the vanadium concentration. Under the identical experimental settings, the suggested approach and the spectrophotometric method were compared, and it was discovered that both were advantageous. The suggested approach technique was straightforward and easy to use, and the findings indicated that it was practical and might be used for on-site analysis. It also had promising properties of mobility and low manufacturing cost, making it appropriate for the detection of vanadium in crude oil.

Keywords: Microfluidics ; Smartphone; Vanadium; 4-(3-(4-Hydroxy-3-methoxyphenyl) acryloyl) phenyl carbamodithioate (HMAPC); Crude oil

Full paper is available at www.springerlink.com.

DOI: 10.1007/s11696-025-03960-6

 

Chemical Papers 79 (4) 2585–2601 (2025)

Monday, April 07, 2025

IMPACT FACTOR 2023
2.1
SCImago Journal Rank 2023
0.381
SEARCH
Advanced
VOLUMES
© 2025 Chemical Papers